Most common reason for failure of rest seat in RPD is :

 # Most common reason for failure of rest seat in RPD is : 
A. Improper rest seat preparation 
B. Contaminated metal 
C. Distorted occlusal rest 
D. Excessive occlusal forces 



The correct answer is A. Improper rest seat preparation.

The most common reason for failure of rest seat in RPD is improper rest seat preparation. Inadequate preparation will result in either occlusal interference or perforation of the metal due to lack of clearance. Failure of rest seat due to contaminated metal or distortion is very rare. 

Reference: McCracken's


The function of reciprocal clasp arm is:

 # The function of reciprocal clasp arm is:
A. To balance the denture 
B. To act as a direct retainer 
C. To counteract the movement of denture which is caused during engagement of retentive arm  
D. None of the above 



The correct answer is C.  To counteract the movement of denture which is caused during engagement of retentive arm 

The rigid reciprocal arm helps in reciprocating stress generated against the tooth by the retentive arm. It also stabilizes the denture against horizontal movement and is always situated above the height of contour. 



Intracoronal retainer placed in the abutment tooth has the following disadvantage:

 # Intracoronal retainer placed in the abutment tooth has the following disadvantage:
A. It is unaesthetic
B. They cannot provide support and stability
C. Difficult laboratory procedures
D. Difficult to repair and replace


The correct answer is D. Difficult to repair and replace.

The advantages of internal or precision attachments are improved esthetics by elimination of a visible retentive component and vertical support. Its disadvantages are difficulty in repair and replacing, greater cost to the patient and inability to use in teeth having short clinical crowns and tissue supported distal extension denture bases. 

A minor connector contacting the axial surface of an abutment should not be located on a:

 # A minor connector contacting the axial surface of an abutment should not be located on a:
A. Flat surface
B. Concavo-convex surface
C. Convex surface
D. Concave surface


The correct answer is C. Convex surface.

Minor connector contacting the axial surface of an abutment should not be located on a convex surface. Instead, it should be located in an embrasure. 

Featured Post

Dental MCQs - Multiple Choice Questions in Dentistry

SELECT THE TOPIC YOU WANT TO PRACTICE. # LOK SEWA  AAYOG PAST QUESTIONS Medical Entrance Preparation MCQs # Digestive System and Nutriti...

Popular Posts